MARUT L G2

Modern outdoor LED luminaire for public lighting with integrated overvoltage protection and adjustable joint ± 15°.

Certification Certification
BIM objects BIM objects
DALI regulation DALI regulation
Mechanical resistance (IK9) Mechanical resistance (IK9)
Degree of protection (IP66) Degree of protection (IP66)
Electromagnetic compatibility Electromagnetic compatibility
Vibration Vibration
ENEC+
ENEC
ZHAGA
Railways

Specifications

Electrical parameters

Light source LED
Power voltage AC 220–240 V / 50–60 Hz
Connection method leading out cable, leading out cable with connector (G), without cable (WO)
Ballast part electronic driver with surge protection L/N-Ground 10 kV
Surge protection additional surge protection 10 kV (S)
Fuse fuse 6,3 A (J)
Possibility of regulation non-dimmable (not labeled), DALI (DALI), night dimming (A)
preparation for wireless communication NEMA (N), Zhaga (Z)
Constant lumen output CLO (C)

Light parameters

Optical system roads (Mxx), roads (Lxx), directional (Pxx), area (Uxx), pedastrian crossing (ZLx/ZPx), combined optics (Kxx), BACK Light clonky (BL1/BL2), FRONT Light clonky (FL1/FL2)
Light distribution direct
Colour rendering index Ra > 70, Ra > 80
Colour temperature BLUE FREE (AMBER) / 2,200 K / 2,700 K / 3,000 K / 4,000 K / 5,000 K / 5 700 K / TW
Service life > 100,000 hrs. (L90B10)

Construction

Luminaire body aluminum cast
Colour RAL 7015/9006
Surface type matte
Luminaire cover tempered glass

Safety

Protection class I, II
Maximum ambient temperature -40 / 55 °C
Protection of the luminaire's electrical part IP 66
Mechanical durability IK 09 
EMC YES
Vibration test YES
Corrosion test – Salty spray YES
Certification ENEC, ENEC+, Zhaga-D4i, IDA Dark Sky Approved
RoHS YES
REACH YES

Mounting

Method pole or boom mounted (48–60 mm); 60–76 mm (on request)
adjustable joint ± 15°
Recommended height max. up to 12 m
Additional equipment  external shades CPZ (on order)
Use outdoor areas; road classes I., II. and III.
 

Variants

Luminaire ambient temperature TQ 25 °C,
Initial color consistency: ≤ 5 SDCM.
Optical and electrical parameters tolerance ± 10 %.
IDA Dark Sky fixture seal of approval relates to ≤ 3 000 K
To meet IDA requirements, the luminaires must be installed horizontally with the road

When using the CLO function, the initial power and luminous flux
is 10 % lower than the value shown in the table. LDT curves with
CLO function have the letter “C” at the end of their marking.

The term BLUE FREE (AMBER) in lighting technology refers to light with a minimum amount of the blue part of the light spectrum (< 2%).

Photometry